How to Size a Micro Storage System for Backup Power

A practical method to match battery capacity and inverter power to the loads you actually need to keep running.

Start with the loads, not the battery

List the appliances you must keep running during an outage and note their running wattage. Add a margin for startup surges — motors and compressors can draw several times their rated power for a few seconds. The sum of simultaneous running watts must stay below the inverter's continuous output.

Convert daily energy to capacity

Multiply each appliance's wattage by the hours you want it to run, then add the results. That is your daily energy need in watt-hours (Wh). For the TEM platform: the 1kWh model stores 1004.8Wh, the 2kWh model 2009.6Wh and the 4kWh model 4019.2Wh. Choose the smallest model that covers your critical loads with some headroom.

Check the solar input

If you want the system to recharge from solar, compare your daily energy use with the maximum PV input: 300W on the 1kWh model, 550W on the 2kWh model and 1200W on the 4kWh model. In regions with limited sun, a larger panel array shortens recharge time.

Don't forget the transfer time

All TEM models switch to battery in under 20ms, which is fast enough for sensitive electronics such as computers and routers. If you run medical or precision equipment, confirm the exact requirements with our engineering team through the quote form.

Send us your load list and target market — we will recommend the right TEM model and confirm it in writing.